ALCATEL-LUCENT ENTERPRISE DATA SHEET
Combo ports are ports individually
congurable to be 10/100/1000 Base-T or
1000Base-X, which spuport SFP transceiv-
ers for short, long and very long distances.
Gigabit ber interfaces on the OmniSwitch
6855-U10 and OmniSwitch 6855-U24X
models support Gigabit SFP or 100Base-X
SFP optical transceivers. See the full list of
supported transceivers at the end of the
data sheet.
POWER SUPPLIES
OmniSwitch 6855 models support redun-
dant, hot-swappable AC, DC or PoE power
supplies. The primary and the backup
power supply units are external, allowing
for easier maintenance and replacement.
There is no interruption of service when
a new power supply is installed or an old
one replaced.
Power supplies for OmniSwitch
6855-14, OmniSwitch 6855-P14
and OmniSwitch 6855-u10
The power supplies for the half rack mod-
els come in the form of a power brick in
either AC or DC variant. A separate power
brick provides PoE power and is available
for purchase when PoE is required.
Power supplies for
OmniSwitch 6855-24 and
OmniSwitch 6855-U24X
The primary and the backup power
supplies for the 24 port models are
modular and connect to the rear of the
unit. A power shelf provided with the unit
can slide into the rear of the switch and is
used to hold two power supplies.
Any power supply can be remotely
connected using a cable, which enables
rack mounting using the mounting ears
provided with the unit. This feature allows
for space-sensitive installations requiring
reduced depth (for example, in a wall-
mounted cabinet).
Indicators
• Per-port LEDs: link/activity/PoE
• System LEDs: OK (switch HW/SW status)
• PS1/PS2: primary and/or redundant power
supply status
• 7-segment LED on OS6855-U24X
indicating the operational mode
and stack number
POWER SUPPLY MODELS DESCRIPTION
OS6855-PSS PSU for OS6855-14 and OS6855-U10; 90 V to 240 V AC, 50 Hz to 60 Hz AC, 40 W, 12 V AC-DC
OS6855-PSS-P PSU for PoE on OS6855-14; 66 W, 48 V PoE, AC-DC
OS6855-PSS-D PSU for 6855-14 and OS6855-U10, 40 W, -48 V and 24 V input to 12 V DC-DC
OS6855-PSS-P-D PSU for PoE on OS6855-14; 66 W, -48 V input DC-DC
OS6855-PSSPH PSU for PoE on OS6855-P14; 185 W PoE, AC-DC
OS6855-PSL-C Fanless PSU for OS6855-U24X; 90 V to 240 V AC, 50 Hz to 60 Hz AC; 80 W, 12 V, AC-DC
OS6855-PSL-P PSU for OS6855-24; 90 V to 240 V AC, 50 Hz to 60 Hz AC; 160 W, 48 VC PoE, 12 V, AC-DC
OS6855-PSL-D PSU for OS6855-24 and OS6855-U24X; 80 W, -48 V/12 V DC-DC
OS6855-PSL-DL PSU for OS6855-24 and OS6855-U24X; 80 W, 24 V/12 V DC-DC
Physical dimensions Weight Depth Width Height
OS6855-PSS, OS6855-PSS-P,
OS6855-PSS-D
0.65 kg (1.3 lb.) 14 cm (5.5 in.) 8.1 cm (3.2 in.) 4.1 cm (1.6 in.)
OS6855-PSS-P-D 0.5 kg (1.1 lb.) 16.6 cm (6.53 in.) 8 cm (3.15 in.) 4.4 cm (1.73 in.)
OS6855-PSSPH 1.03 kg (2.27 lb.) 11.35 cm (4.47 in.) 6.3 cm (2.48 in.) 12.52 cm (4.93 in.)
Power brick tray 0.5 kg (1.35 lb.) 19.1 cm (7.5 in.) 21.6 cm (8.5 in.) 4.4 cm (1.73 in.)
Power supply (AC, DC or PoE) 1.00 kg (2.20 lb.) 16.5 cm (6.5 in.) 16 cm (6.3 in.) 4.4 cm (1.73 in.)
Power supply tray 0.60 kg (1.32 lb.) 17.8 cm (7.0 in.) 35.3 cm (13.88 in.) 4.4 cm (1.73 inn.)
OS6855P14 OS685514 OS685524 OS6855U10 OS6855U24X
Environment
Operating temperature -40°C to +70°C
(-40°F to +158°F)
-40°C to +70°C
(-40°F to +158°F)
-40°C to +75°C
(-40°F to +167°F)
-40°C to +70°C
(-40°F to +158°F)
-40°C to +70°C
(-40°F to +158°F)
Storage temperature -40°C to +85°C
(-40°F to +185°F)
-40°C to +85°C
(-40°F to +185°F)
-40°C to +85°C
(-40°F to +185°F)
-40°C to +85°C
(-40°F to +185°F)
-40°C to +85°C
(-40°F to +185°F)
Humidity (operating and storage) 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95%
MTBF* (hours) 387,985 430,389 529,644 508,942 373,980
Fanless design Yes Yes No Yes Yes***
Acoustic (dB) at <50°C Silent Silent 33 Silent Silent
Acoustic (dB) – all fans on N/A N/A 57 N/A N/A
Power consumption**** 33.5 W 30 W 46 W 25 W 51 W
Heat dissipation** (BTU/hr) 114.3 102.4 157 85.3 174
MTBF values calculated at 25•C (77°F) for the switch only
** Sufcient spacing required for airow and heat dissipation
*** The OS6855-U24X chassis is fanless. The etxernal DC power supplies have fans.
**** Power consumption was measured from the AC input power using nominal input voltage of 120 V AC and runnnig full trafc on all ports.