Mounting OS6400 Switches Hot-Swapping Power Supplies
OmniSwitch 6400 Series Hardware Users Guide July 2010 page 3-23
Hot-Swapping Power Supplies
OmniSwitch 6400 Series switches support hot-swapping of their power supplies. The following sections
describe how to hot-swap a power supply either directly connected (i.e., without a cable) or rack-mounted
power supply.
Warning: Before proceeding, ensure a redundant power supply is connected and operational.
Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding
strap, or by grounding yourself properly. Static discharge can damage the switch and the backup power
supply.
Hot-Swapping a Power Supply Connected to the Rear
of the Chassis
1 Disconnect the power supply to be hot-swapped from its power source.
2 Loosen the captive screw of the power supply to be hot-swapped.
3 Carefully slide the power supply out of the power supply shelf and set aside.
Directly Connected Power Supply
4 Carefully slide the new power supply onto the shelf and against the back of the chassis until the power
connector securely connects
5 Tighten the captive screw for the new power supply to the power supply shelf.
6 Re-connect the power supply to its power source.